Circuit Breaker for Motor Protection S00, 0.7...1 A
Circuit breaker size S00 for motor protection, CLASS 10 A-trip 0.7...1 A N-trip 13 A screw terminal Standard breaking capacity. Standard breaking capacity 3RV2011-0JA10
Available immediately
Circuit Breaker for Motor Protection S00, 7...10 A
Circuit breaker size S00 for motor protection, CLASS 10 A trip 7...10 A N trip 130 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2011-1JA10
Available immediately
Circuit Breaker for Motor Protection S00, 1.4...2 A
Circuit breaker, size S00, for motor protection; CLASS 10, A-trip 1.4...2 A, N-trip 26 A, screw terminals, standard breaking capacity. Standard breaking capacity 3RV2011-1BA10
Available immediately
Circuit breaker for motor protection, S00, 4.5...6.3 A
Circuit breaker, size S00, for motor protection; CLASS 10, A-trip 4.5...6.3 A, N-trip 82 A, screw terminals, standard breaking capacity. Standard breaking capacity 3RV2011-1GA10
Available immediately
Circuit Breaker for Motor Protection S00, 0.18...0.24 A
Circuit breaker size S00 for motor protection, CLASS 10 A trip 0.18...0.25 A N trip 3.3 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2011-0CA10
Available immediately
Circuit Breaker for Motor Protection S00, 5.5...8 A
Circuit breaker, size S00, for motor protection, CLASS 10 A-trip 5.5...8 A N-trip 104 A screw terminals standard breaking capacity. Standard breaking capacity 3RV2011-1HA10
Available immediately
Circuit breaker for the motor protection S2, 42–52 A
Circuit breaker, size S2, for motor protection, CLASS 20, A-trip 42...52 A, N-trip 741 A, screw terminals, standard breaking capacity. Standard breaking capacity 3RV2031-4WB10
Delivery time on requestk
Circuit Breaker for Motor Protection S0, 34...40 A
Circuit breaker size S0 for motor protection, CLASS 10 A trip 34...40 A N trip 480 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2021-4FA10
Available immediately
Circuit breaker for motor protection S00, 5.5–8.0 A
Circuit breaker size S00 for motor protection, CLASS 10 A-trip unit 5.5...8 A N-trip unit 104 A spring-operated connection standard breaking capacity with transverse auxiliary switch 1S+1Ö. Standard breaking capacity spring-operated 3RV2011-1hA25
Delivery time on requestk
Circuit breaker for motor protection S00, 3.5–5.0 A
Circuit breaker size S00 for motor protection, CLASS 10 A-trip unit 3.5...5 A N-trip unit 65 A spring-loaded terminal Standard breaking capacity with transverse auxiliary switch 1NO+1NC. Standard breaking capacity spring-loaded terminal 3RV2011-1FA25
Delivery time on requestk
Circuit breaker for motor protection S3, 65 ... 84 A
Circuit breaker size S3 for motor protection, CLASS 20 A-trip unit 65...84 A N-trip unit 1170 A screw terminal increased breaking capacity 100 kA. increased breaking capacity 100kA 3RV2042-4RB10
Delivery time on requestk
Circuit breaker for motor protection, S0, 14...20 A
Circuit breaker size S0 for motor protection, CLASS 10 A trip 13...20 A N trip 260 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2021-4BA10
Available immediately
Circuit Breaker for the Motor Protection S2, 49–59 A
Circuit breaker size S2 for motor protection, CLASS 20 A-trip 49...59 A N-trip 845 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2031-4XB10
Delivery time on requestk
Circuit breaker for motor protection S3, 36...50 A
Circuit breaker size S3 for motor protection, CLASS 20 A trip unit 36...50 A N trip unit 650 A screw connection increased breaking capacity 100 kA. increased breaking capacity 100kA 3RV2042-4HB10
Delivery time on requestk
Circuit breaker for motor protection S2, 18...25 A
Circuit breaker size S2 for motor protection, CLASS 20 A trip 18...25 A N trip 325 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2031-4DB10
Delivery time on requestk
Circuit Breaker for Motor Protection, S0, 27...32 A
Circuit breaker, size S0, for motor protection; CLASS 10, A-trip 27...32 A, N-trip 400 A, screw terminals, standard breaking capacity. Standard breaking capacity 3RV2021-4EA10
Available immediately
S00 circuit breaker for motor protection, 3.5...5 A
Circuit breaker, size S00, for motor protection; CLASS 10, A-trip 3.5...5 A, N-trip 65 A, screw terminals, standard breaking capacity. Standard breaking capacity 3RV2011-1FA10
Available immediately
Circuit breaker for transformer protection S3, 57...75 A
Circuit breaker size S3 for motor protection, CLASS 20 A-trip unit 57...75 A N-trip unit 975 A screw terminal increased breaking capacity 100 kA. increased breaking capacity 100 kA 3RV2042-4KB10
Delivery time on requestk
Circuit Breaker for the Motor Protection S2, 28–36 A
Circuit breaker size S2 for motor protection, CLASS 20 A trip 32...40 A N trip 585 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2031-4UB10
Delivery time on requestk
Circuit breaker for motor protection S00, 4.5–6.3 A
Circuit breaker size S00 for motor protection, CLASS 10 A trip unit 4.5...6.3 A N trip unit 82 A spring-operated connection standard breaking capacity with transverse auxiliary switch 1S+1Ö. Standard breaking capacity spring-operated 3RV2011-1GA25
Delivery time on requestk
Circuit breaker for motor protection S00, 0.45...0.63 A
Circuit breaker size S00 for motor protection, CLASS 10 A trip 0.45...0.63 A N trip 8.2 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2011-0GA10
Available immediately
Circuit breaker for motor protection, size S0, 11...16 A
Circuit breaker size S0 for motor protection, CLASS 10 A-trip 10...16 A N-trip 208 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2021-4AA10
Delivery time on requestk
Circuit Breaker for Motor Protection, S0, 30...36 A
Circuit breaker size S0 for motor protection, CLASS 10 A-trip 30...36 A N-trip 432 A screw terminals standard breaking capacity. Standard breaking capacity 3RV2021-4PA10
Available immediately
Circuit Breaker for Motor Protection S00, 1.1...1.6 A
Circuit breaker size S00 for motor protection, CLASS 10 A-trip 1.1...1.6 A N-trip 21 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2011-1AA10
Available immediately