Filter products
- News
- Manufacturers
- Components
- Enclosures
- Services
- Downloads
Auxiliary contactor, 3 N.O./1 N.C., 24V DC coil
700-K Mini auxiliary contactors, double contacts for low voltages, optional integrated coil free-wheeling diode.The 700-K IEC auxiliary contactor is a compact industrial relay capable of switching low voltages and providing performance features required for demanding industrial applicationsrequired—positively driven/mechanically linked contacts, time modules, longcontact life—in an IEC design. These relays use the same accessories as theequivalent 100-IEC contactors. 700-K31Z-ZJ
Available immediately
Circuit Breaker for Transformer Protection, Thermal Trip: 0.63...1.0 A
140MT – Features and benefits, Extended current range for more applications:,140MT-C up to 32 A – 140MT-D up to 40 A, Improved thermal performancereduces heat loss, Protection and control functions: overload protection, high short-circuit protection, disconnection function and phase failure protection, Suitable for special applications: variable frequency drives (VFD)in multi-motor applications(140MT-D9V), Highly efficient motor protection with high inrush current (140MT-D9T), Motor protection switch optionfor three-component starters (140MT-D9N), UL branch circuit protection classes allow for smaller conductors in group motor installations, thereby reducing installation costs. Self-protected (Type E) combination motor controller classes eliminate the need for separate branch circuit protection. Easy documentation with SCCR tool for certifying combination tests. with 100-E, 100-C and 100-K contactors. Magnetic trip unit: 16...22 x Ie, Ika: 100 kA 140MT-D9T-B10
Available immediately
Auxiliary contactor, 2 N.O./ 2 N.C., 24 V DC coil
700-K Mini auxiliary contactor, double contacts for low voltages, optional integrated coil free-wheeling diode.The 700-K IEC auxiliary contactor is a compact industrial relay capable of switching low voltages and providing performance features required for demanding industrial applicationsrequired—positively driven/mechanically linked contacts, time modules, longcontact life—in an IEC design. These relays use the same accessories as theequivalent 100-IEC contactors. 700-K22Z-ZJ
Available immediately
Auxiliary contactor, 2 N.O./2 N.C., 24 V DC coil, diode
700-K Mini auxiliary contactor, double contacts for low voltages, optional integrated coil free-wheeling diode.The 700-K IEC auxiliary contactor is a compact industrial relay capable of switching low voltages and providing performance features required for demanding industrial applicationsrequired—positively driven/mechanically linked contacts, time modules, longcontact life—in an IEC design. These relays use the same accessories as theequivalent 100-IEC contactors. 700-K22Z-DJ
Available immediately
Circuit Breaker for Transformer Protection, Thermal Trip: 1.0...1.6 A
140MT – Features and Benefits, Extended current range for more applications:,140MT-C up to 32 A – 140MT-D up to 40 A, Improved thermal performancereduces heat loss, Protection and control functions: overload protection, high short-circuit protection, disconnection function and phase failure protection, Suitable for special applications: variable frequency drives (VFD)in multi-motor applications(140MT-D9V), Highly efficient motor protection with high inrush current (140MT-D9T), Motor protection switch optionfor three-component starters (140MT-D9N), UL branch circuit protection classes allow for smaller conductors in group motor installations, thereby reducing installation costs. Self-protected (Type E) combination motor controller classes eliminate the need for separate branch circuit protection. Easy documentation with SCCR tool for certification of combination tests. with 100-E, 100-C and 100-K contactors. Magnetic trip unit: 16...22 x Ie, Ika: 100kA 140MT-D9T-B16
Available immediately
3-pole circuit breaker, surface-mount, 25A, without actuator
Surface-mount 194E-A25-1753
Available immediately
Auxiliary contactor, 4 N.O., 24V DC coil
700-K Mini auxiliary contactor, double contacts for low voltages, optionally integrated coil freewheeling diode.The 700-K IEC auxiliary contactor is a compact industrial relay that can switch low voltages and provide performance features required for demanding industrial applicationsrequired – positively guided/mechanically linked contacts, timing modules, longcontact life – in an IEC design. These relays use the same accessories as theequivalent 100-IEC contactors. 700-K40E-ZJ
Available immediately
Safety Auxiliary Contactor, 6A/400V, 24V DC with E-Coil
Safety Auxiliary Contactor, 6A/400V, 24V DC with E-coil, 6N.O. & 2N.C. AC-15 with gold-plated fork contacts 700S-CF620EJBC
Available immediately
Circuit Breaker for Motor Protection, Thermal Trip: 4.0...6.3 A
140MT – Features and Benefits, Extended current range for more applications:,140MT-C up to 32 A – 140MT-D up to 40 A, Improved thermal performancereduces heat loss, Protection and control functions: overload protection, high short-circuit protection, disconnection function and phase failure protection, Suitable for special applications: variable frequency drives (VFD)in multi-motor applications(140MT-D9V), highly efficient motor protection with high inrush current (140MT-D9T), motor protection switch optionfor three-component starters (140MT-D9N), UL branch circuit protection classes allow for smaller conductors in group motor installations and thus reduce installation costs. Self-protected (Type E) combination motor controller classes eliminate the need for separate branch circuit protection. Easy documentation with SCCR tool for certifying combination tests. with 100-E, 100-C and 100-K contactors. Magnetic trip unit: 14 x Ie, Ika: 100 kA 140MT-C3E-B63
Available immediately
Circuit Breaker for Transformer Protection, Thermal Trip: 2.5...4.0 A
140MT – Features and Benefits, Extended current range for more applications:,140MT-C up to 32 A – 140MT-D up to 40 A, Improved thermal performanceReduces heat loss, protection and control functions: overload protection, high short-circuit protection, disconnection function and phase failure protection, Suitable for special applications: variable frequency drives (VFD)in multi-motor applications(140MT-D9V), highly efficient motor protection with high inrush current (140MT-D9T), motor protection switch optionfor three-component starters (140MT-D9N), UL branch circuit protection classes allow for smaller conductors in group motor installations, thereby reducing installation costs. Self-protected (Type E) combination motor controller classes eliminate the need for separate branch circuit protection. Easy documentation with the SCCR tool for certifying combination tests. with 100-E, 100-C and 100-K contactors. Magnetic trip unit: 16...22 x Ie, Ika: 100 kA 140MT-D9T-B40
Available immediately
Circuit Breaker for Motor Protection, Thermal Trip: 4.0...6.3 A
140MP – Features and Benefits, Protection and Control Functions: Overload protection, high short-circuit protection, disconnection function, and phase failure protection.Suitable for three-phase and single-phase applications, motor with UL group and IEC Type 1 and Type 2 markings, CE, cULus, CCC, KC, and EAC certification, breaking capacity at 400 V: up to100 kA. Magnetic trip unit: 13 x Ie, Ika: 50 kA 140MP-A3E-B63
Available immediately
Circuit Breaker for Motor Protection, Thermal Trip: 2.5...4.0 A
140MT – Features and Benefits, Extended current range for more applications:,140MT-C up to 32 A – 140MT-D up to 40 A, Improved thermal performancereduces heat loss, protection and control functions: overload protection, high short-circuit protection, disconnection function and phase failure protection, suitable for special applications: variable frequency drives (VFD)in multi-motor applications(140MT-D9V), highly efficient motor protection with high inrush current (140MT-D9T), motor protection switch optionfor three-component starters (140MT-D9N), UL branch circuit protection classes allow for smaller conductors in group motor installations, thereby reducing installation costs. Self-protected (Type E) combination motor controller classes eliminate the need for separate branch circuit protection. Easy documentation with the SCCR tool for certifying combination tests. with 100-E, 100-C and 100-K contactors. Magnetic trip unit: 14 x Ie, Ika: 100 kA 140MT-C3E-B40
Available immediately
Circuit Breaker for Motor Protection, Thermal Trip: 1.0...1.6 A
140MT – Features and Benefits, Extended current range for more applications:,140MT-C up to 32 A – 140MT-D up to 40 A, Improved thermal performancereduces heat loss, protection and control functions: overload protection, high short-circuit protection, disconnection function and phase failure protection, suitable for special applications: variable frequency drives (VFD)in multi-motor applications(140MT-D9V), highly efficient motor protection with high inrush current (140MT-D9T), motor protection switch optionfor three-component starters (140MT-D9N), UL branch circuit protection classes allow for smaller conductors in group motor installations and thus reduce installation costs. Self-protected (Type E) combination motor controller classes eliminate the need for separate branch circuit protection. Easy documentation with the SCCR tool for certification of combination tests. with 100-E, 100-C and 100-K contactors. Magnetic trip unit: 14 x Ie, Ika: 100 kA 140MT-C3E-B16
Available immediately
Safety Contactor, AC-3 400V, 4kW, 9A, 3-pole
Auxiliary contacts 2S / 3Ö, 24V DC coil, diode 100S-C09EJ23C
Available immediately
Circuit Breaker for Motor Protection, Thermal Trip: 1.6...2.5 A
140MP – Features and Benefits, Protection and Control Functions: Overload protection, high short-circuit protection, disconnection function, and phase failure protection.Suitable for three-phase and single-phase applications, motor with UL group and IEC Type 1 and Type 2 markings, CE, cULus, CCC, KC, and EAC certification, breaking capacity at 400 V: up to100 kA. Magnetic trip unit: 13 x Ie, Ika: 75 kA 140MP-A3E-B25
Available immediately
Auxiliary contactor, 4 N.O., 24 V DC solenoid
700-CF Auxiliary Contactors, Mechanically Linked, Forced-Guided Contacts, Gold-Plated Double Contacts for Low Voltages (700-CF), Main control relay version with a rated current of 15 A (AC-15, 700-CF), Add-On Auxiliary Control Blocks (front- or side-mounting). The 700-CF IEC auxiliary contactor is a compact industrial relay that can switch low voltages and provide performance features that are required for demanding industrial applicationsrequired – forcibly guided/mechanically linked contacts, timing modules, longcontact life – in an IEC design. These relays use the same accessories as theequivalent 100-IEC contactors. 700-CF400EJ
Available immediately
Circuit Breaker for Motor Protection, Thermal Trip: 6.3...10 A
140MT – Features and Benefits, Extended current range for more applications:,140MT-C up to 32 A – 140MT-D up to 40 A, Improved thermal performanceReduces heat loss, Protection and control functions: overload protection, High short-circuit protection, Disconnection function and phase failure protection, Suitable for special applications: variable frequency drives (VFD)in multi-motor applications(140MT-D9V), Highly efficient motor protection with high inrush current (140MT-D9T), Motor protection switch optionfor three-component starters (140MT-D9N), UL branch circuit protection classes allow for smaller conductors in group motor installations and thus reduce installation costs. Self-protected (Type E) combination motor controller classes make separate branch circuit protection unnecessary. Easy documentation with SCCR tool for certification of combination tests. with contactors 100-E, 100-C and 100-K. Magnetic trip unit: 14 x Ie, Ika: 100kA 140MT-C3E-C10
Available immediately
Circuit Breaker for Motor Protection, Thermal Trip: 0.63...1.0 A
140MT – Features and Benefits, Extended current range for more applications:,140MT-C up to 32 A – 140MT-D up to 40 A, Improved thermal performancereduces heat loss, Protection and control functions: Overload protection, High short-circuit protection, Disconnection function and phase failure protection, Suitable for special applications: Variable frequency drives (VFD)in multi-motor applications(140MT-D9V), Highly efficient motor protection with high inrush current (140MT-D9T), Motor protection switch optionfor three-component starters (140MT-D9N), UL branch circuit protection classes allow smaller conductors in group motor installations, thus reducing installation costs. Self-protected (Type E) combination motor controller classes eliminate the need for separate branch circuit protection. Easy documentation with the SCCR tool for certifying combination tests. with 100-E, 100-C and 100-K contactors. Magnetic trip unit: 14 x Ie, Ika: 100 kA 140MT-C3E-B10
Available immediately
Circuit Breaker for Transformer Protection, Thermal Trip: 4.0...6.3 A
140MT – Features and Benefits, Extended current range for more applications:,140MT-C up to 32 A – 140MT-D up to 40 A, Improved thermal performancereduces heat loss, Protection and control functions: overload protection, high short-circuit protection, disconnection function and phase failure protection, Suitable for special applications: variable frequency drives (VFD)in multi-motor applications(140MT-D9V), highly efficient motor protection with high inrush current (140MT-D9T), motor protection switch optionfor three-component starters (140MT-D9N), UL branch circuit protection classes allow for smaller conductors in group motor installations, thereby reducing installation costs. Self-protected (Type E) combination motor controller classes eliminate the need for separate branch circuit protection. Easy documentation with the SCCR tool for certifying combination tests. with 100-E, 100-C and 100-K contactors. Magnetic trip unit: 16...22 x Ie, Ika: 100 kA 140MT-D9T-B63
Available immediately
Auxiliary contactor, 4 N.O., 230 V AC coil
700-K Mini auxiliary contactor, double contacts for low voltages, optionally integrated coil free-wheeling diode.The 700-K IEC auxiliary contactor is a compact industrial relay that can switch low voltages and provide performance features for demanding industrial applicationsrequired - positively driven/mechanically linked contacts, timing modules, longcontact life - in an IEC design. These relays use the same accessories as theequivalent 100-IEC contactors. 700-K40E-KF
Available immediately
Thermal motor protection relay for 100-C.., 0.45...0.63 A
193-T1 bimetallic motor protection relay Basic motor protection device, overload protection – trip class 10, phase loss protection, designed for power converter and variable frequency drive applications up to 400 Hz, 1 NO and 1 NC auxiliary contact. 193-T1 bimetallic motor protection relays were developed for use with 100-C and 104-C series contactors. 193-T1AA63
Available immediately
Circuit Breaker for Motor Protection, Thermal Trip: 2.5...4.0 A
140MP – Features and Benefits, Protection and Control Functions: Overload protection, high short-circuit protection, disconnection function, and phase failure protection.Suitable for three-phase and single-phase applications, motor with UL group and IEC Type 1 and Type 2 markings, CE, cULus, CCC, KC, and EAC certification, breaking capacity at 400 V: up to100 kA. Magnetic trip unit: 13 x Ie, Ika: 75 kA 140MP-A3E-B40
Available immediately
Auxiliary contactor, 3 N.O./ 1 N.C., 230 V AC coil
700-K Mini auxiliary contactors, double contacts for low voltages, optional integrated coil free-wheeling diode.The 700-K IEC auxiliary contactor is a compact industrial relay capable of switching low voltages and providing performance featuresrequired for demanding industrial applications – positively driven/mechanically linked contacts, time modules, longcontact life – in an IEC design. These relays use the same accessories as theequivalent 100-IEC contactors. 700-K31Z-KF
Available immediately
Circuit Breaker for Motor Protection, Thermal Trip: 6.3...10 A
140MP – Features and Benefits, Protection and Control Functions: Overload protection, high short-circuit protection, disconnection function, and phase failure protection.Suitable for three-phase and single-phase applications, motor with UL group and IEC Type 1 and Type 2 markings, CE, cULus, CCC, KC, and EAC certification, breaking capacity at 400 V: up to100 kA. Magnetic trip unit: 13 x Ie, Ika: 50 kA 140MP-A3E-C10
Available immediately
Do you have specific requirements?
We’ll provide you with personalized advice and work with you to find the right solution for your application.