Soft starter, 200–480 V AC, 37 kW, 70 A, Us = 24 V AC/DC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 24 V AC/DC, control voltage: UC = 24 V AC, 24 V DC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 37 kW, at 460 V, 60 Hz: P = 50 HP, Rated operating current AC-53: Ie = 70 A, Rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS3, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134918
Delivery time on requestk
Soft starter, 200–480 V AC, 11 kW, 24 A, Us = 110–230 V AC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 110–230 V AC, control voltage: UC = 110–230 V AC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 11 kW, at 460 V, 60 Hz: P = 15 HP, rated operating current AC-53: Ie = 24 A, rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS2, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134931
Delivery time on requestk
Soft starter, 200–480 V AC, 75 kW, 135 A, Us = 24 V AC/DC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 24 V AC/DC, control voltage: UC = 24 V AC, 24 V DC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 75 kW, at 460 V, 60 Hz: P = 100 HP, Rated operating current AC-53: Ie = 135 A, Rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS4, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134921
Delivery time on requestk
Soft starter, 200–480 V AC, 55 kW, 100 A, Us = 24 V AC/DC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 24 V AC/DC, control voltage: UC = 24 V AC, 24 V DC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 55 kW, at 460 V, 60 Hz: P = 75 HP, Rated operating current AC-53: Ie = 100 A, Rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS3, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA 22.2-14 Y7-134920
Delivery time on requestk
Soft starter, 200–480 V AC, 5.5 kW, 12 A, Us = 110–230 V AC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 110–230 V AC, control voltage: UC = 110–230 V AC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 5.5 kW, at 460 V, 60 Hz: P = 10 HP, rated operating current AC-53: Ie = 12 A, rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS1, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA 22.2-14 Y7-134929
Delivery time on requestk
Soft starter, 200–480 V AC, 7.5 kW, 16 A, Us = 110–230 V AC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 110–230 V AC, control voltage: UC = 110–230 V AC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 7.5 kW, at 460 V, 60 Hz: P = 10 HP, rated operating current AC-53: Ie = 16 A, rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS2, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134930
Delivery time on requestk
Soft starter, 200–480 V AC, 90 kW, 160 A, Us = 24 V AC/DC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 24 V AC/DC, control voltage: UC = 24 V AC, 24 V DC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 90 kW, at 460 V, 60 Hz: P = 125 HP, Rated operating current AC-53: Ie = 160 A, Rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS4, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134922
Delivery time on requestk
Soft starter, 200–480 V AC, 4 kW, 9 A, Us = 110–230 V AC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 110–230 V AC, control voltage: UC = 110–230 V AC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 4 kW, at 460 V, 60 Hz: P = 5 HP, Rated operating current AC-53: Ie = 9 A, Rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS1, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA 22.2-14 Y7-134928
Delivery time on requestk
Soft starter, 200–480 V AC, 3 kW, 7 A, Us = 110–230 V AC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 110–230 V AC, control voltage: UC = 110–230 V AC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 3 kW, at 460 V, 60 Hz: P = 5 HP, Rated operating current AC-53: Ie = 7 A, Rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS1, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA 22.2-14. Y7-134927
Delivery time on requestk
Soft starter, 200–480 V AC, 22 kW, 41 A, Us = 24 V AC/DC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 24 V AC/DC, control voltage: UC = 24 V AC, 24 V DC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 22 kW, at 460 V, 60 Hz: P = 30 HP, Rated operating current AC-53: Ie = 41 A, Rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS3, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134916
Delivery time on requestk
Soft starter, 200–480 V AC, 37 kW, 70 A, Us = 110–230 V AC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 110–230 V AC, control voltage: UC = 110–230 V AC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 37 kW, at 460 V, 60 Hz: P = 50 HP, rated operating current AC-53: Ie = 70 A, rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS3, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134936
Delivery time on requestk
Soft Starter, 200–480 V AC, 45 kW, 81 A, Us = 110–230 V AC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 110–230 V AC, control voltage: UC = 110–230 V AC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 45 kW, at 460 V, 60 Hz: P = 60 HP, rated operating current AC-53: Ie = 81 A, rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS3, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA 22.2-14 Y7-134937
Delivery time on requestk
Soft starter, 200–480 V AC, 15 kW, 32 A, Us = 110–230 V AC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 110–230 V AC, control voltage: UC = 110–230 V AC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 15 kW, at 460 V, 60 Hz: P = 25 HP, rated operating current AC-53: Ie = 32 A, rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS2, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134932
Delivery time on requestk
Soft starter, 200–480 V AC, 30 kW, 55 A, Us = 110–230 V AC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 110–230 V AC, control voltage: UC = 110–230 V AC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 30 kW, at 460 V, 60 Hz: P = 40 HP, rated operating current AC-53: Ie = 55 A, rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS3, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA 22.2-14 Y7-134935
Delivery time on requestk
Soft starter, 200–480 V AC, 45 kW, 81 A, Us = 24 V AC/DC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 24 V AC/DC, control voltage: UC = 24 V AC, 24 V DC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 45 kW, at 460 V, 60 Hz: P = 60 HP, Rated operating current AC-53: Ie = 81 A, Rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS3, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134919
Delivery time on requestk
Soft starter, 200–480 V AC, 55 kW, 100 A, Us = 110–230 V AC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 110–230 V AC, control voltage: UC = 110–230 V AC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 55 kW, at 460 V, 60 Hz: P = 75 HP, rated operating current AC-53: Ie = 100 A, rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS3, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134938
Delivery time on requestk
Soft starter, 200–480 V AC, 1.5 kW, 4 A, Us = 24 V AC/DC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 24 V AC/DC, control voltage: UC = 24 V AC, 24 V DC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 1.5 kW, at 460 V, 60 Hz: P = 2 HP, rated operating current AC-53: Ie = 4 A, rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS1, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134847
Delivery time on requestk
Soft starter, 200–480 V AC, 110 kW, 200 A, Us = 110–230 V AC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 110–230 V AC, control voltage: UC = 110–230 V AC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 110 kW, at 460 V, 60 Hz: P = 150 HP, rated operating current AC-53: Ie = 200 A, rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, Size: FS4, Standards and regulations: IEC/EN 60947-4-2, UL 508, CSA 22.2-14 Y7-134941
Delivery time on requestk
Soft starter, 200–480 V AC, 22 kW, 41 A, Us = 110–230 V AC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 110–230 V AC, control voltage: UC = 110–230 V AC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 22 kW, at 460 V, 60 Hz: P = 30 HP, rated operating current AC-53: Ie = 41 A, rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS3, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134934
Delivery time on requestk
Soft starter, 200–480 V AC, 90 kW, 160 A, Us = 110–230 V AC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 110–230 V AC, control voltage: UC = 110–230 V AC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 90 kW, at 460 V, 60 Hz: P = 125 HP, rated operating current AC-53: Ie = 160 A, rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS4, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA 22.2-14 Y7-134940
Delivery time on requestk
Soft starter, 200–480 V AC, 1.5 kW, 4 A, Us = 110–230 V AC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 110–230 V AC, control voltage: UC = 110–230 V AC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 1.5 kW, at 460 V, 60 Hz: P = 2 HP, rated operating current AC-53: Ie = 4 A, rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS1, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134925
Delivery time on requestk
Soft starter, 200–480 V AC, 5.5 kW, 12 A, Us = 24 V AC/DC
Soft Starter, Description: with internal bypass contacts, Function: soft starter for three-phase loads, Mains voltage (50/60 Hz): ULN = 200–480 V AC, Supply voltage: Us = 24 V AC/DC, control voltage: UC = 24 V AC, 24 V DC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 5.5 kW, at 460 V, 60 Hz: P = 10 HP, Rated operating current AC-53: Ie = 12 A, Rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS1, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134911
Delivery time on requestk
Soft starter, 200–480 V AC, 15 kW, 32 A, Us = 24 V AC/DC
Soft Starter, Description: with internal bypass contacts, Function: soft starter for three-phase loads, Mains connection voltage (50/60 Hz): ULN = 200–480 V AC, Supply voltage: Us = 24 V AC/DC, control voltage: UC = 24 V AC, 24 V DC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 15 kW, at 460 V, 60 Hz: P = 25 HP, Rated operating current AC-53: Ie = 32 A, Rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connectivity: no, size: FS2, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134914
Delivery time on requestk
Soft starter, 200–480 V AC, 3 kW, 7 A, Us = 24 V AC/DC
Soft starter, description: with internal bypass contacts, function: soft starter for three-phase loads, line voltage (50/60 Hz): ULN = 200–480 V AC, supply voltage: Us = 24 V AC/DC, control voltage: UC = 24 V AC, 24 V DC, rated motor power (standard connection, in-line) at 400 V, 50 Hz: P = 3 kW, at 460 V, 60 Hz: P = 5 HP, rated operating current AC-53: Ie = 7 A, rated operating voltage: Ue = 200 V, 230 V, 400 V, 480 V, SmartWire-DT connection: no, size: FS1, standards and regulations: IEC/EN 60947-4-2, UL 508, CSA22.2-14 Y7-134849
Delivery time on requestk